146 3080 000(1)2006-10 A SW 750
DUST FILTER CLEANING AND INTEGRITY
CHECK, HOPPER GASKET CHECK
Drive the machine on a level ground.
Turn the main switch (1) to “0”.
Remove the hopper (9).
Loosen the knobs (A, Fig. 8).
Grasp the dust fi lter (B) as shown in the fi gure.
Remove the dust fi lter by turning it in the direction shown
by the arrow (A, Fig. 9) to disengage it from the pins (B),
then lower the fi lter to disengage it from the fi lter shaker
combs (C).
Remove the fi lter (A, Fig. 10) from the frame (B) by
disengaging the 3 rubber bands (C).
In an appropriate outdoor area, clean the fi lter by shaking
it on a level and clean surface, tapping the side (D)
opposite to the gasket (E).
Complete the cleaning procedure by using compressed
air (F) at maximum 6 Bars, blowing only from the side of
the gasket (E), at a minimum distance of 30 cm.
Do not use water or detergents to clean it, otherwise it
can be damaged.
Check the fi lter body for tears. If necessary, replace it.
Clean the bearing surface of the fi lter rubber gasket
(E) and check it for integrity and sealing capabilities. If
necessary, replace the fi lter.
Clean the bearing surface of the hopper gasket (D, Fig.
9) and check it for integrity and sealing capabilities. If
necessary, replace it.
Assemble in the reverse order of disassembly.
NOTE
Assemble the fi lter with the gasket (E, Fig. 10)
positioned as shown in the fi gure.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
S311357
Figure 8
S311358
Figure 9
S311359
Figure 10
A
B
A
B
B
D
A
C
D
A
F
B
C
E
Page view 53