Nilfisk-ALTO ATTIX 550-2M User Manual Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 18
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
15
english
ATTIX 360-2M
ATTIX 550-2M / ATTIX 560-2MXC
ATTIX 751-2M / ATTIX 761-2MXC
1)
Option depending on model
EC declaration of conformity
Alto Deutschland GmbH
Guido-Oberdorfer-Straße 2-8
D-89287 Bellenberg
Product:
Model:
Description:
The design of the appliance
corresponds to the following
pertinent regulations:
Applied harmonized standards:
Applied national standards and
technical specifications:
Dipl.-Ing. Wolfgang Nieuwkamp
Tests and approvals
Vacuum cleaner for wet and dry operation
ATTIX 360-2M/550-2M/560-2MXC
ATTIX 751-2M/761-2MXC
110/230-240 V~, 50/60 Hz, 1200 W, Dust class M
EC Machine Directive 98/37/EC
EC Low Voltage Directive 73/23/EC
EC EMC Directive 89/336/EC
EN 12100-1, EN 12100-2
EN 60335-1
EN 60335-2-69
EN 55014-1, EN 55014-2, EN 61000-3-2
DIN EN 60335-1
DIN EN 60335-2-69
Bellenberg, 22.10.2004
Suction hose diameter
mm
Minimum air flow volume
l/min
Associated negative pressure
between suction hose/tool
Pa
27 690 16300
32 970 15700
36 1220 14200
50 2360 7800
9.5 Accessories
Description Order No.
360-2M 550-2M 560-2MXC
Filter bag (5 pcs.) 302000449 302000527 302001138
Waste bag (5 pcs.) 302000804 302000728
Filter element 302000461 302000726
Cloth insert filter 302000606 302000525
751-2M 761-2MXC
Filter bag (5 pcs.) 302001484
Waste bag (5 pcs.) 302001480
Filter element 302000461 302000726
Cloth insert filter 302000525
360-2M / 550-2M / 560-2MXC
751-2M / 761-2MXC
Protective filter bag
(10 pcs.)
30082
Filter screen 15475
Nilfisk-Alto-Foam-
Stop (6 x 1 l)
8469
9.6 EC declaration of conformity
9.4 Technical data
ATTIX
360-2M 550-2M 560-2MXC 751-2M 761-2MXC
EU
GB
230/240V
EU
GB
230/240V
GB
110V
EU EU EU
Voltage V 230 230/240 230 230/240 110 230 230 230
Mains frequency Hz 50/60
Fuse A 16 13 16 13 16 16 16 16
Power consumption W 1200
Connected load for
appliance socket
W 2400 1800 2400 1800 560 2400 2400 2400
Total connected load W 3600 3000 3600 3000 1760 3600 3600 3600
Volume flow (air) l/min 3600
Negative pressure Pa 23000
Measurement area sound
pressure level at a distance of
1 m, EN 60704-1
dB(A) 62 60
Operating noise dB(A) 59 57
Power cord: Length m 7,5 10.0 7,5 10.0 7,5 7,5 7,5 7,5
Power cord: Length
H05RR- F3G1,5
H07BQ-
F3G1,5
H05RR-
F3G1,5
H05RR- F3G1,5
Protection class I
Type of protection
(splash water protec-
ted)
IP X4
Radio interference
level
EN 55014-1
Tank volume l 27 45 70
Width mm 380 476 580
Depth mm 390 506 605
Height mm 570 655 970
Weight kg 10 14 25 27
Page view 16